Security professionals around the world have been using FLIR thermal cameras for perimeter and critical asset security for years. Facility Operations and Safety personnel have been using FLIR cameras to gather non-contact temperature measurements and condition monitoring data for decades. A310F and A310PT cameras are the first in the world to combine thermal and visible light video security imaging with automated safety monitoring based on the detection of temperature measurement thresholds.

Protecting perimeters and monitoring vital equipment.

  • Perimeter security

    Dual thermal and visible payloads, with analytics, provide best-in-class intrustion detection.

  • Equipment monitoring

    By measuring slight changes in surface temperature, the FLIR A310PT can detect hotspots or overheating equipment.

  • Wide-area surveillance for fire detection

    If the camera detects temperatures that exceed pre-set levels, it generates an alarm, alerting security personnel of potential threats.

Specifiche
Panoramica
Funzioni di allarme
6 automatic alarms on any selected measurement function, camera temperature
Riscaldatore automatico
Clears window from ice. Switched on at +4°C (39°F). Switched off at +15°C (59°F).
Escursione in azimut
Az velocity 360° continuous, 0.1 to 60°/sec max
Tipo sensore
Focal Plane Array (FPA), uncooled microbolometer
Escursione in elevazione
El velocity ± 45°, 0.1 to 30°/sec. max
Lunghezza focale
76 mm (3.0 in.)
Materiale alloggiamento
Aluminum
Risoluzione IR
320 × 240 pixels
Contenuto
Cardboard box, Pan & tilt with infrared camera including lens, and visual camera, FLIR Sensors Manager download card, Lens cap, Printed documentation, Small accessories kit, User documentation CD-ROM
Dimensioni imballo
671 x 564 x 464 mm (26.4 x 22.2 x 18.3 in.)
Alimentazione
24 VAC (21-30 VAC; 24 VAC: 215 VA max. with heater) or 24 VDC (21-30 VDC; 24 VDC: 195 W max. with heater).
Comandi di configurazione
Date/time, Temperature°C/°F
Dimensioni (L × P × A)
460 × 467 × 326 mm (18.1 × 18.4 × 12.8 in.)
Banda spettrale
7.5–13 µm
Peso
17.8 kg (39.3 lb.)
Zoom
1–8× continuous, digital, interpolating zooming on images
Ambientale
Correzione della trasmissione atmosferica
Automatic, based on inputs for distance, atmospheric temperature and relative humidity
Urti
5 g, 11 ms (IEC 60068-2-27)
EMC
EN 61000-6-2 (Immunity), EN 61000-6-3 (Emission) , FCC 47 CFR Part 15 Class B (Emission)
Correzione emissività
Variable from 0.01 to 1.0
Protezione
IP 66 (IEC 60529)
Umidità (esercizio e stoccaggio)
IEC 60068-2-30/24 h 95% relative humidity +25° C to +40°C (+77°F to +104°F)
Range di temperature di esercizio
–25°C to +50°C (-13°F to +122°F)
Range di temperature di stoccaggio
–40°C to +70°C (–40°F to +158°F)
Vibrazione
2 g (IEC 60068-2-6)
Connessioni e comunicazioni
Ethernet
Control, result and image
Comunicazione Ethernet
TBA
Tipo connettore Ethernet
RJ-45
Protocolli Ethernet
Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Ethernet standard
IEEE 802.3
Tipo Ethernet
100 Mbps
Streaming video via Ethernet
Two independent channels for each camera - MPEG-4, H.264, or M-JPEG
Uscita video
Composite video output, PAL /NTSC compatible
Imaging e ottiche
Tavolozze colori
Color palettes (BW, BW inv, Iron, Rain)
Pitch sensore
25 µm
Costante di tempo del sensore
Typical 12 ms
Pixel effettivi
380.0
Zoom elettronico
12× continuous, digital, interpolating
numero f
1.3
Campo visivo (FOV)
6° × 4.5°
Focal Plane Array (FPA)
1/4” Exview HAD CCD
Messa a fuoco
Automatic or manual (built in motor)
Frequenza immagine
9Hz
Identificazione ottica
Automatic
Distanza minima di messa a fuoco
4 m (13.11 ft.) 
Zoom ottico
36× continuous
Risoluzione spaziale (IFOV)
0.33 mrad 
Standard video
CVBS (ITU-R-BT.470 PAL), CVBS (SMPTE 170M NTSC)
Misurazioni e analisi
Accuratezza
±4°C (±7.2°F) or ±4% of reading
Area
10 boxes with max./min./average/position
Ottiche esterne e Correzione finestre
Automatic, based on input of optics/window transmission and temperature
Isoterme
1 with above/below/interval
Correzioni misurazione
Global and individual object parameters
Range di temperature oggetto
–20 to +120°C (–4 to +248°F) 0 to +350°C (+32 to +662°F)
Correzione della trasmittanza ottica
Automatic, based on signals from internal sensors
Preset programmabili
128.0
Correzione della temperatura riflessa apparente
Automatic, based on input of reflected temperature
Puntatore a spot
10.0
Sensibilità termica/NETD
< 0.05°C @ +30°C (+86°F) / 50 mK
[Missing text '/pages/productpage/presalecontact/contactsales' for 'Italian (Italy)']

Vuoi maggiori informazioni su questo prodotto?

Chiama +44 (0) 203 747 6768 per parlare con uno specialista.

Prodotti correlati
Restrizioni all'esportazione

Restrizioni all'esportazione

Le informazioni contenute in questa pagina si riferiscono ad un prodotto "dual-use", di cui l'esportazione è regolamentata dalle normative Export Administration Regulations (EAR). È vietata qualsiasi deroga a tali normative degli Stati Uniti. Non è richiesta autorizzazione del Dipartimento del Commercio degli Stati Uniti (US Department of Commerce) per l’esportazione o il trasferimento a persone o entità estere salvo altrimenti vietato.

TRITON™ A310 PT (Security) - Model: FLIR A310pt, 6° (9 Hz) PAL

Change Selection